51
SAFETY
INFORMATIONS
Vibrations and sound level
OPERATION AND MAINTENANCE INSTRUCTION MANUAL
HBR204-MU-6-eng.doc
THIS DOCUMENT IS THE PROPERTY OF HÜETTE BOHRTECHNIK GMBH - TOTAL OR PARTIAL REPRODUCTION IS PROHIBITED
3.5. Vibrations and sound level
Sound level
The machine was designed and manufactured using every technological solution possible to
reduce noise power and noise pressure levels at the source via soundproofing of the engine
compartment.
Measured sound power level
L
WA
111 dB
2.32
Guaranteed sound power level
L
WAd
113 dB
2.33
Sound pressure level in the operator position:
Adjustment and start-up control panel (A)
L
pA
85 dB
Work positions for operator with use of radio remote control (B)
L
pA
< 84 dB
3.5.1