![Hutt HBR 204 Operation And Maintenance Instruction Manual Download Page 143](http://html1.mh-extra.com/html/hutt/hbr-204/hbr-204_operation-and-maintenance-instruction-manual_2190084143.webp)
131
OPERATION
Electronic control system
OPERATION AND MAINTENANCE INSTRUCTION MANUAL
HBR204-MU-6-eng.doc
THIS DOCUMENT IS THE PROPERTY OF HÜETTE BOHRTECHNIK GMBH - TOTAL OR PARTIAL REPRODUCTION IS PROHIBITED
N°
Indication of
the group to
which the error
belongs
Indication of the
specific
element of the
group
ITALIANO
ENGLISH
18
100
2
Errore PLC 2
Errore di comunicazione
PLC 2 error
Error in communication
18a
100
3
Errore PLC 3
Errore di comunicazione
PLC 3 error
Error in communication
18b
100
4
Errore PLC 4
Errore di comunicazione
PLC 4 error
Error in communication
18c
100
5
Errore PLC 5
Errore di comunicazione
PLC 5 error
Error in communication
19
50
0
Filtro antiparticolato. Il ciclo di
rigenerazione del filtro
antiparticolato sta per entrare in
funzione
Particulate filter. The cycle of
regeneration of the particle
filter is about to be in operation
20
200
0
Il dispositivo collegato all'uscita
del PLC (elettrovalvola o altro) è
guasto (regolazione cilindrata
pompe P1-P2)
The device connected to the
PLC output (solenoid valve,
etc.) is broken (adjustment of
pump displacement P1-P2)
21
60
2
Il dispositivo collegato all'uscita
del PLC (elettrovalvola o altro) è
guasto (traslazione testa) S250
The device connected to the
PLC output (solenoid valve,
etc.)
is
broken
(head
movement) S250
22
58
9
Serbatoio
olio
idraulico
–
Apertura della saracinesca
Hydraulic oil tank
– Opening
the gate