Drag the power supply
PS 307 2A
in the catalog to position 1 of the rack with
SIMATIC
300
PS-300
PS 307 2A
Drag CPU
317F-2 PN/DP
in the catalog to position 2 of the rack with
SIMATIC 300
CPU-300
CPU 317F-2 PN/DP
6ES7 317-2FK13-0AB0
V2.3
. Also specify the characteristics of the
Ethernet interface
here if necessary.
Drag digital output module
SM 326F DO 10xDC24V/2A
in the catalog to position 4 of the
rack with
SIMATIC 300
SM-300
DO-300
SM 326F DO 10xDC24V/2A
(6ES7 326-2BF01-0AB0)
Drag digital input module
SM 326F DI 24xDC24V
in the catalog to position 5 of the rack
with
SIMATIC 300
SM-300
DI-300
SM 326F DI 24xDC24V
(6ES7 326-1BK01-0AB0)
The hardware components to be included in the rack are now complete.
The GSD file
HUEB0E3F.GSE
belonging to the measuring system must be installed in the next
step. This is copied into the installation directory of the
SIMATIC Manager
:
…\S7DATA\GSD
.
The bitmap file
HUEB_BDE.bmp
belonging to the measuring system is copied into the following
folder:
…\S7DATA\NSBMP
. You should note that the directory structure can vary.