Absolute Encoder AMP(H) 41
AMP(H)41_MANUAL-en_R11 - 2019-03-28
85
11.2.1.1
Station status 1
Standard diagnosis byte 1
Bit 7
Master_Lock
Slave has been parameterized from another master (bit is
set by the master)
Bit 6
Parameter_Fault
The parameter telegram last sent has been rejected by the
slave
Bit 5
Invalid_Slave_Response
Is set by the master, if the slave does not respond.
Bit 4
Not_Supported
Slave does not support the requested functions.
Bit 3
Ext_Diag
Bit = 1 means an extended diagnosis report from the slave
is waiting.
Bit 2
Slave_Cfg_Chk_Fault
The configuration identifier(s) sent from the master has
(have) been rejected by the slave.
Bit 1
Station_Not_Ready
Slave is not ready to exchange cyclical data.
Bit 0
Station_Non_Existent
The slave has been configured, but is not available on the
bus.
11.2.1.2
Station status 2
Standard diagnosis byte 2
Bit 7
Deactivated
Slave was removed from the poll list from the master.
Bit 6
Reserved
Bit 5
Sync_Mode
Is set by the slave after receipt of the SYNC command.
Bit 4
Freeze_Mode
Is set by the slave after receipt of the FREEZE command.
Bit 3
WD_On
The response monitoring of the slave is activated.
Bit 2
Slave_Status
Always set for slaves
Bit 1
Stat_Diag
Statistic diagnosis
Bit 0
Prm_Req
The slave sets this bit if it has to be reparameterized and
reconfigured.
11.2.1.3
Station status 3
Standard diagnosis byte 3
Bit 7
Ext_Diag_Overflow
Overflow for extended diagnosis
Bit 6-0
Reserved
11.2.1.4
Master address
Standard diagnosis byte 4
The slave enters the station address of the master into this byte, after the master has sent a
valid parameterization telegram. To ensure correct function on the PROFIBUS it is imperative
that, in the case of simultaneous access of several masters, their configuration and
parameterization information exactly matches.
Summary of Contents for AMP 41
Page 96: ...96 AMP H 41_MANUAL en_R11 2019 03 28 Absolute Encoder AMP H 41 16 3 T V certificate...
Page 97: ...Absolute Encoder AMP H 41 AMP H 41_MANUAL en_R11 2019 03 28 97 16 4 PROFIBUS DP certificate...
Page 98: ...98 AMP H 41_MANUAL en_R11 2019 03 28 Absolute Encoder AMP H 41 16 5 PROFIsafe certificate...