![Hubner AMP 41 Operating And Assembly Instructions Manual Download Page 22](http://html1.mh-extra.com/html/hubner/amp-41/amp-41_operating-and-assembly-instructions-manual_2180893022.webp)
22
AMP(H)41_MANUAL-en_R11 - 2019-03-28
Absolute Encoder AMP(H) 41
4.5
Mounting of AMP 41, construction type B5 (flange)
Fig. 2: AMP 41, construction type B5 (mounting example)
DANGER! NOTICE!
Danger of death, serious physical injury and/or damage to property due to
deactivation of safety functions, caused by an unstable mounting!
It is the responsibility of the user to ensure the screwed connections used to
secure the encoder are properly dimensioned and that the mounting process is
carried out in accordance with best practices.
Ensure the centering is implemented to tolerance Ø85 H7 (0 / +0.035).
1.
Fit coupling (2) onto (motor) shaft (1).
2.
Secure the coupling hub on the (motor) shaft (1) using the clamping screw.
3.
Lightly grease the (motor) centering (1a).
4.
Fasten the intermediate flange (3) to the motor using the fastening screws (4).
5.
Lightly grease the intermediate flange centering (3a).
6.
Fit the encoder (7) into both the centering (3a) and coupling hub (2) at the same time.
7.
Secure the encoder (7) to the intermediate flange (3) using at least 4 M6 screws (8) of
the property class 8.8 and washers to ISO 7090 - 6 - 200 HV distributed evenly around
the circumference!
8.
Secure the coupling hub (2) on the encoder shaft using the clamping screw.
9.
Screw in the sealing plug (5) to seal the access bore to the coupling.
3a
4
2
3
6
5
7
1a
1
8
Summary of Contents for AMP 41
Page 96: ...96 AMP H 41_MANUAL en_R11 2019 03 28 Absolute Encoder AMP H 41 16 3 T V certificate...
Page 97: ...Absolute Encoder AMP H 41 AMP H 41_MANUAL en_R11 2019 03 28 97 16 4 PROFIBUS DP certificate...
Page 98: ...98 AMP H 41_MANUAL en_R11 2019 03 28 Absolute Encoder AMP H 41 16 5 PROFIsafe certificate...