The position actual values of both measuring systems are compared for safe transmission. If
the difference is less than the set monitoring window, the value is considered safe. The safe
position actual value and the calculated safe speed value are transmitted via the PROFIsafe
profile. The part of the control which performs the safety-oriented functions can then process
these values.
●
The position actual value and the calculated speed value of the first measuring system are
directly transmitted in the unsafe process data channel. This channel is generally processed
more frequently by the control. This allows normal automation processes to access the
updated position value more frequently.
Fig. 10: Measuring system
– PROFIsafe communication
Profibus Protocol
Process Data Channel
Saving Channel (F-Channel)
Data of system 1:
Position
Speed
Data of System 1, verified
with System 2
Position
Speed
Control
Secured part of the control
Safety Relevant
Functions
Secured Data Traffic
Normal part of the control
Normal Automation
Functions, e.g. Position
Control...
Short Cycle Time
0,5ms
5ms