![Huawei V100R006C00 Configuration Manual Download Page 95](http://html.mh-extra.com/html/huawei/v100r006c00/v100r006c00_configuration-manual_169533095.webp)
7.11.3 Configuring Flow Mirroring
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
observe-port
index
interface
interface-type interface-number
An observing port is configured.
Step 3
Run:
traffic behavior
behavior-name
A traffic behavior is created and the traffic behavior view is displayed.
Step 4
Run:
mirroring
to observe-port
index
Flow mirroring is configured.
----End
Follow-up Procedure
After configuring flow mirroring in a traffic behavior, you need to bind the behavior to a traffic
classifier in a traffic policy and then apply the policy to the interface. For detailed configuration
procedures, see
7.11.4 Creating and Applying a Traffic Policy
7.11.4 Creating and Applying a Traffic Policy
Context
Do as follows on the S5700 that needs to be configured with flow mirroring.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
traffic policy
policy-name
A traffic policy is created and the policy view is displayed.
Step 3
Run:
classifier
classifier-name
behavior
behavior-name
A traffic behavior is configured for a specified class in the traffic policy.