Step 2
Run:
info-center trapbuffer
[
channel
{
channel-number
|
channel-name
} |
size
buffersize
]
*
Information is sent to the trap buffer.
----End
6.3.6 Sending Information to the Log Host
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
info-center loghost
ip-address
[
channel
{
channel-number
|
channel-name
} |
facility
local-number
| {
language
language-name
|
binary
[
port
] } | {
vpn-
instance
vpn-instance-name
|
public-net
} ]
*
Information is sent to the IPv4 log host.
Step 3
Run:
info-center loghost
ipv6
ipv6-address
[
channel
{
channel-number
|
channel-name
}
|
facility
local-number
| {
language
language-name
|
binary
[
port
] } ]
*
Information is sent to the IPv6 log host.
Step 4
Run:
info-center loghost source
interface-type
interface-number
The source interface for sending logs is specified.
----End
6.3.7 Checking the Configuration
Run the following commands to check the previous configuration.
Action
Command
Check statistics in the
information center.
display info-center
[
statistics
]
Run the preceding command. If the information center can send the statistics to the destination
terminal, it means that the configuration succeeds.
6.4 Maintaining the Information Center
This section describes how to clear the statistics.