Table 3-9
Parameters of the AC rectifier modules
Item
Parameter
Dimensions (H x W x D)
41.5 mm x 183.8 mm x 201 mm (1.63 in. x
7.24 in. x 7.91 in.)
Weight
2.5 kg (5.51 lb)
Rated voltage
110 V AC / 220 V AC
Input voltage range
90 V AC — 290 V AC
Maximum input current
10 A
Maximum output power
1600 W
Table 3-10
Indicator Description
Indicat
or
Name
Color
Norm
al
Statu
s
Abnor
mal
Status
Remarks
Input
indicato
r
Green
On
Off
If the indicator is on, the input is normal. If the
indicator is off, the input is abnormal.
Blink
Overvoltage or undervoltage is input.
The panel switch is Off.
Output
indicato
r
Green
On
Off
If the indicator is on, the output is normal. If the
indicator off, the output is abnormal.
Fault
indicato
r
Red
Off
Blink
The indicator is blinking in the following
situations:
The communication is interrupted for 60s or longer.
The power is input unevenly.
The AC power module is reset remotely.
On
The indicator is blinking in the following
situations:
Protection against overtemperature is performed.
Fans become faulty.
3.3 Heat Dissipation System
The heat dissipation system is responsible for the heat dissipation of the entire device. Heat
generated by the boards is dissipated through the heat dissipation system. In this manner, the
temperatures of the components on the boards are controlled within a normal range, enabling
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
3 CX600-X2-M16 Hardware Description
Issue 03 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
72