Item
Specification
Storage temperature
-40°C to +70°C (-40°F to 158°F)
Ambient
relative
humidity
Long-term
5% RH to 85% RH, noncondensing
Short-term
5% RH to 95% RH, noncondensing
Storage relative humidity
0% RH to 95% RH, noncondensing
Long-term working altitude
Lower than 3000 m (9842.4 ft)
Storage altitude
Lower than 5000 m (16404 ft)
NOTE
In the dimensions shown in the table, the width (W) does not include the rack-mounting ears.
Temperature and humidity are measured at 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) in front of the
cabinet. There should be no protection board on the front or back of the cabinet.
"Short-term" refers to continuous working time that does not exceed 96 hours and accumulated working time
per year that does not exceed 15 days. If the working time exceeds either of these values, it is considered "long-
term".
The device cannot start at an ambient temperature lower than -20°C (-4°F).
Product Specifications
Table 1-4
System configuration list of the CX600-X1-M4
Item
Description
Processing unit
Main frequency: 1.2 GHz
SDRAM
2 GB
Flash
16 MB
eUSB
2 GB
Switching capacity
240 Gbit/s (NPU-120\120-E)
100 Gbit/s (NPU-50\50-E)
Interface capacity
NPU-120\120-E:240 Gbit/s
NPU-50\50-E: 100 Gbit/s
Number of NPU slots
1
Number of PIC slots
4
Number of MPU slots
2
Maximum port rate supported by
PICs or NPU
10 Gbit/s
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
1 CX600-X1-M4 Hardware Description
Issue 03 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7