l
Data forwarding plane
The NPUs are responsible for service processing in the entire system, and are connected
to all subcards through data channels.
Table 2-15
NPU parameters
Item
Description
Remarks
Forwarding capability
50 Gbit/s
-
Figure 2-17
Appearance of the NPU panel
1. STAT indicator
2. ACT indicator
3. OFL button
describes the buttons and indicators on the NPU panel.
Table 2-16
Description of the buttons and indicators on the NPU panel
Indicator/
Button
Description
STAT
indicator
If the indicator is on, the NPU is working properly.
If the indicator blinks green, NPU is being registered.
If the indicator is off, the NPU is faulty, not powered on, or fails to be registered.
ACT
indicator
If the indicator is steady green, the NPU is in the master state.
If the indicator is off, the NPU is in the slave state or fails to be registered.
OFL
indicator
If the indicator is steady red, the NPU is powered off and can be safely removed.
If the indicator is off, the NPU is working properly.
OFL
button
This button indicates the removal of the NPU. Before removing the NPU, press
and hold the OFL button for 6s until the OFL indicator comes on. Then, you
can remove the NPU.
2.4.4 Introduction to the NPU-120
NOTE
NPU-120 must not be installed in an outdoor cabinet.
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
2 CX600-X2-M8 Hardware Description
Issue 03 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
50