Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameter
HD3L Series Controller User Manual
―
87
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
1: Connects with common
terminal
d03.02
Output terminal status
Display in 16-bit binary:
Bit15 - Bit6 Unused
Bit5 - Bit2 correspond to RLY4 -
RLY1
Bit1 - Bit0 correspond to DO2 -
DO1
Positive logic: 0 stands for
invalid while 1 stands for valid
Negative logic: 0 stands for valid
while 1 stands for invalid
Actual
*
d03.03 MODBUS
status
0: Normal
1: Communication timeout
2: Incorrect data frame head
3: Incorrect data frame checking
4: Incorrect data frame content
Actual
*
d03.04
Total time at power-on (hour)
0 - 65535
Actual
*
d03.05
Total running time (hour)
0 - 65535
Actual
*
d03.06
Running times
0 - 65535
Actual
*
d03.07
Present fault
0 - 100
Actual
*
F00: Basic Parameters, on pages 46 - 47
F00.00
Motor type
0: Asynchronous motor
0
1
×
F00.01 Motor
control
mode
0: V/f control
1: SVC control
1 1
×
F00.02
Rated speed of elevator
0.100 - 4.000m/s
1.500m/s
0.001m/s
×
F00.03
Max. output frequency of
HD3L
5.00 - 100.00Hz
50.00Hz
0.01Hz
×
F00.04
Mechanical parameters of
motor
10.0 - 6000.0
60.0
0.1
×
F00.05 Operating
mode
0: Keypad control
1: Terminal analogue control
2: Terminal MS control
0 1
×
F00.06 M-key
function
0: Unused
1: UP / DN switch
0 1
○
F00.07
Speed setting of keypad
0.000m/s - F00.02
1.500m/s
0.001m/s
○
F00.08 Run
direction
0: The same as run command
1: Opposite to run command
0 1
×
F01: Protection of Parameters, on pages 47 - 48
F01.00
User’s password
00000 - 65535
00000
1
○
F01.01 Menu
mode
0: Full menu mode
1: Checking menu mode
(display parameters different
from factory setting only)
0 1
○