Chapter 7 Elevator application guidance
Shenzhen Hpmont Technology Co., Ltd.
―
74
―
HD3L Series Controller User Manual
Ref. Code
Function
Value
Remark
F04.04
Corresponding value of line 1 max.
setting
100.0%
F04.05
Line 2 min. setting
0.0%
F04.06
Corresponding value of line 2 min.
setting
0.0%
F04.07
Line 2 max. setting
100.0%
F04.08
Corresponding value of line 2 max.
setting
100.0%
F06.00
Pre-torque selection
1
Analogue weighing feedback
F06.01 Up
pre-torque
bias
50.0%
Set according to actual situation
and debug according to running
effect.
F06.02 Down
pre-torque
bias
50.0%
F06.03
Up electrical pre-torque gain
1.000
F06.04
Up brake pre-torque gain
1.000
F06.05
Down electrical pre-torque gain
1.000
F06.06
Down brake pre-torque gain
1.000
F12.01
DI1 function
1
Controller enabled (EN)
F12.02 DI2
function
2
UP
F12.03 DI3
function
3
DN
F12.15 DO1
function
2 Controller
is
running
F12.16
DO2 function
3
Controller is at zero-speed running
F12.17
RLY1 function
14
Controller fault
F13.00
AI1 function
1
Speed setting
F13.01
AI2 function
2
Weighing signal
F13.04 / F13.07
AI1/ AI2 bias
0.0%
Adjust according to actual
situation
F13.05 / F13.08
AI1/ AI2 gain
1.00
F13.06 / F13.09
AI1/ AI2 filter time
0.05s