Table 7-2 Terminal MS run parameter
Ref. Code
Function
Value
Remark
F00.05
Operating mode
2
Terminal MS control
F02.02
Retention time of start zero-speed
0.5s
Adjust according to the situation of
running contactor and brake at
motor start & stop.
F02.06
Retention time of stop zero-speed
0.5s
F03.00 Acc
speed
0.700m/s
2
Set according to the elevator speed
and running effect.
F03.01 Start
Acc
jerk
0.350m/s
3
F03.02
End Acc jerk
0.600m/s
3
F03.03 Dec
speed
0.700m/s
2
F03.04 Start
Dec
jerk
0.600m/s
3
F03.05
End Dec jerk
0.350m/s
3
F03.06
Inspection Acc speed
0.200m/s
2
F03.07
Inspection Dec speed
1.000m/s
2
F03.13
Stop Dec jerk
0.350 m/s
3
F05.00 Multi-speed
0
0
As actual value
F05.01 Multi-speed
1
Re-leveling
speed
F05.02 Multi-speed
2
Creeping
speed
F05.03
Multi-speed 3
Battery driven speed
F05.04 Multi-speed
4
Inspection
speed
F05.05
Multi-speed 5
Normal low speed
F05.06
Multi-speed 6
Normal mid speed
F05.07
Multi-speed 7
Normal high speed
F12.01
DI1 function
1
Controller enabled (EN)
F12.02 DI2
function
2
UP
F12.03 DI3
function
3
DN
F12.04 DI4
function
4
MS1
F12.05 DI5
function
5
MS2
F12.06 DI6
function
6
MS3
F12.15 DO1
function
2 Controller
is
running
F12.16
DO2 function
3
Controller is at zero-speed running
F12.17
RLY1 function
14
Controller fault
F16.07
Multi-speed inspection
4
Multi-speed inspection selection