Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
―
44
―
HD3L Series Controller User Manual
6.1.3
d02: Analogue Status Display Parameters
Ref. Code
Function Description
Setting Range [Default]
d02.00 AI1
voltage
[Actual value]
Display AI1 input voltage.
d02.01
AI1 voltage (after calculating)
[Actual value]
Display A1 input voltage which is calculated by the gain, bias and filter.
d02.02 AI2
voltage
[Actual value]
Display AI2 input voltage.
When selects current input, -10.00V corresponds to 0mA, and 10.00V corresponds to 20mA.
d02.03
AI2 voltage (after calculating)
[Actual value]
Display AI2 input voltage which is calculated by the gain, bias and filter.
d02.04 AI3
voltage
[Actual value]
Display AI3 input voltage.
When selects current input, -10.00V corresponds to 0mA, and 10.00V corresponds to 20mA.
d02.05
AI3 voltage (after calculating)
[Actual value]
Display AI3 input voltage which is calculated by the gain, bias and filter.
d02.06 AI4
voltage
[Actual value]
Display AI4 input voltage.
When selects current input, -10.00V corresponds to 0mA, and 10.00V corresponds to 20mA.
d02.07
AI4 voltage (after calculating)
[Actual value]
Display AI4 input voltage which is calculated by the gain, bias and filter.
d02.08 AO1
output
[Actual value]
Display
AO1
output.
When selects current output, 0V corresponds to 0mA, and 10.00V corresponds to 20mA.
d02.09 AO2
output
[Actual value]
Display
AO2
output.
When AO2 selects current output, 0V corresponds to 0mA, and 10.00V corresponds to 20mA.