Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameter
HD3L Series Controller User Manual
―
95
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F15.12
Set parameter 5 of stop status
26: Input terminal status
27: Output terminal status
28: MODBUS state
29: Total time at power on (hour)
30: Total running time (hour)
31,32: Unused
27 1
○
F15.13
Set parameter 6 of stop status
0
1
○
F16: Function-boost Parameters, on pages 64 - 66
F16.00
Zero-speed running signal
delay time
0.00 - 10.00s
0.30s
0.01s
×
F16.01
Zero-speed signal delay time
0.00 - 10.00s
0.30s
0.01s
×
F16.02
Current keep time after stop
0 - 9999ms
0ms
1ms
×
F16.03 Fan
control
0: Auto stop
1: Immediately stop
2: Run when power on
0 1
○
F16.04
Fan control delay time
0.0 - 600.0s
30.0s
0.1s
○
F16.05
Brake unit action voltage
220V: 380 - 450V
380V: 630 - 750V
Depend
on HD3L
1V
×
F16.06
Detection time of contactor
fault
0.1 - 10.0s
2.0s
0.1s
×
F16.07
Multi-speed inspection
0 - 7
0
1
×
F16.08
Zero-speed threshold
0.001 - 0.010m/s
0.003m/s
0.001m/s
○
F16.09
Selection at motor overheat
fault
0: Alarm fault after motor stops
1: Alarm fault at once
0 1
○
F16.10 – F16.11 Unused
F16.12
Delay time of run output
signal
0.00 - 1.00s
0.00s
0.01s
×
F16.13
UPS running direction
auto-determine enable
0: Not enable
1: Enable
0 1
×
F16.14
Running min. current limit
0 - 100% (F07.11)
20%
1%
×
F16.15
Running min. detection time
0.0 - 5.0s
0.0s
0.1s
×
F16.16
Governor fault detection time
0.0 - 2.0s
1.0s
0.1s
×
F16.17
DC braking current at stop
0 – 150%
100%
1%
×
F16.18
Starting frequency of DC
braking current at stop
0.20 - 10.00Hz
0.50Hz
0.01Hz
×
F16.19
Brake release frequency
0.00 - 10.00Hz
0.00Hz
0.01Hz
×
F16.20 - F16.24 Unused
F17: Fault Protect Parameters, on pages 66 - 68
F17.00
Input voltage at motor
overheat
0.00 -10.00V
0.00V
0.01V
×
F17.01 Thermistor
type
0: Not detect the motor
overheat
1: Positive charateristic
2: Negative charateristic
0 1
×
F17.02
Threshold resistance at motor
0.0 - 10.0kΩ
5.0kΩ
1.0kΩ
×
A