Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameter
HD3L Series Controller User Manual
―
97
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F17.11
NO.5 fault type
E0022: Read / Write fault of
keypad EEPROM
(display on the keypad only,
HD3L does not protect it)
E0023: Faulty setting of
parameters
E0024: Fault of external
equipment
E0025: Too small running
current
E0028: SCI ommunication
timeout
E0029: SCI communication error
E0032: Motor over speed
E0036: Contator fault
E0037: Governor fault
E0008, E0010, E0013, E0014,
E0021, E0022, E0024, E0036 can’t
auto reset
0 1 *
F17.12
Setting freqency at NO.5 fault
0.00 - 100.00Hz
0.00Hz
0.01Hz
*
F17.13
Output freqency at NO.5 fault
0.00 - 100.00Hz
0.00Hz
0.01Hz
*
F17.14
DC bus vlotage at NO.5 fault
0 - 999V
0V
1V
*
F17.15
Output voltage at NO.5 fault
0 - 999V
0V
1V
*
F17.16
Output current at NO.5 fault
0.0 - 999.9A
0.0A
0.1A
*
F17.17
Input terminal status at NO.5
fault
0 - 0x1FF
0
1
*
F17.18
Output terminal status at
NO.5 fault
0 - 0x3F
0
1
*
F17.19
NO.5 fault interval
0.0 - 6553.5 hours
0.0h
0.1h
*
F17.20
NO.4 fault type
0 - 36
0
1
*
F17.21
NO.4 fault interval
0.0 - 6553.5 hours
0.0h
0.1h
*
F17.22
NO.3 fault type
0 - 36
0
1
*
F17.23
NO.3 fault interval
0.0 - 6553.5 hours
0.0h
0.1h
*
F17.24
NO.2 fault type
0 - 36
0
1
*
F17.25
NO.2 fault interval
0.0 - 6553.5 hours
0.0h
0.1h
*
F17.26
NO.1 fault type
0 - 36
0
1
*
F17.27
NO.1 fault interval
0.0 - 6553.5 hours
0.0h
0.1h
*
F18: PWM Parameters, on page 68
F18.00
Carrier frequency
1 - 16kHz
Depend
on HD3L
1kHz
×
F18.01
Carrier freqency auto adjust
selection
0: Unused
1: Enable
0 1
×
F18.02
PWM overmodulation enable
0: Unused
1: Enable
1 1
×
F18.03
PWM overmodulation mode
0: Two / Three phase swtich
0
1
×
A