Appendix A Parameter
Shenzhen Hpmont Technology Co., Ltd.
―
94
―
HD3L Series Controller User Manual
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
3: 9600bps
4: 19200bps
5: 38400bps
F14.02
Local address
0 - 247
2
1
×
F14.03
Host PC response time
0 - 1000ms
0ms
1ms
×
F14.04
Detection time of
communication timeout
0.0 - 1000.0s
0.0: Not detect at timeout
0.0s 0.1s
×
F14.05
Detection time of
communication error
0.0 - 1000.0s
0.0: Not detect at error
0.0s 0.1s
×
F14.06 - F14.47 Unused
F15: Display Control Parameters, on pages 63 - 64
F15.00 Language
selection
0: Chinese
1: English
2 - 9: Unused
0 1
○
F15.01
Display contrast of the LCD
keypad
1 - 10
5
1
○
F15.02
Set parameter 1 of run status
0: Unused
1: Rated current of HD3L
2: Controller status
3: Operate channel
4: Setting speed
5: Setting speed (after Acc / Dec)
6: Output frequency
7: Setting RPM
8: Running RPM
9: Unused
10: Output voltage
11: Output current
12: Output torque
13: Output power
14: DC bus voltage
15: AI1 voltage
16: AI1 voltage (after
calculating)
17: AI2 voltage
18: AI2 voltage (after
calculating)
19: AI3 voltage
20: AI3 voltage (after
calculating)
21: AI4 voltage
22: AI4 voltage (after
calculating)
23, 24: AO1, AO2 output
25: Heatsink temperature
5 1
○
F15.03
Set parameter 2 of run status
6
1
○
F15.04
Set parameter 3 of run status
10
1
○
F15.05
Set parameter 4 of run status
11
1
○
F15.06
Set parameter 5 of run status
0
1
○
F15.07
Set parameter 6 of run status
0
1
○
F15.08
Set parameter 1 of stop status
4
1
○
F15.09
Set parameter 2 of stop status
14
1
○
F15.10
Set parameter 3 of stop status
16
1
○
F15.11
Set parameter 4 of stop status
26
1
○