Appendix A Parameter
Shenzhen Hpmont Technology Co., Ltd.
―
86
―
HD3L Series Controller User Manual
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
Bit13: Stop signal
Bit14,Bit15: Unused
d01: Drive Status Parameters, on pages 43 -44
d01.00
Control mode
0 - 5
Actual
*
d01.01
Setting speed (m/s)
0.000 - 9.999
Actual
*
d01.02
Setting speed (after Acc /
Dec) (m/s)
0.000 - 9.999
Actual
*
d01.03
Feedback speed (m/s)
0.000 - 9.999
Actual
*
d01.04
Setting frequency (Hz)
0.01 - 100.00Hz
Actual
*
d01.05
Setting frequency (after Acc /
Dec)
0.01 - 100.00Hz
Actual
*
d01.06
Output frequency
0.01 - 100.00Hz
Actual
*
d01.07
Setting RPM
0 - 24000RPM
Actual
*
d01.08
Running RPM
0 - 24000RPM
Actual
*
d01.09 Unused
d01.10
Output voltage
0 - 999V
Actual
*
d01.11
Output current
0.1 - 999.9A
Actual
*
d01.12 Output
torque
0.0 - 300.0% (motor rated
torque)
Actual
*
d01.13 Output
power
0.0 - 200.0% (motor rated
power)
Actual
*
d01.14
DC bus voltage
0 - 999V
Actual
*
d01.15 - d01.16 Unused
d02: Analogue Status Display Parameters, on pages 44 - 45
d02.00
AI1 voltage
0.00 -10.00V
Actual
*
d02.01
AI1 voltage (after calculating)
0.00 -10.00V
Actual
*
d02.02
AI2 voltage
0.00 -10.00V
Actual
*
d02.03
AI2 voltage (after calculating)
0.00 -10.00V
Actual
*
d02.04
AI3 voltage
0.00 -10.00V
Actual
*
d02.05
AI3 voltage (after calculating)
0.00 -10.00V
Actual
*
d02.06
AI4 voltage
0.00 -10.00V
Actual
*
d02.07
AI4 voltage (after calculating)
0.00 -10.00V
Actual
*
d02.08
AO1 output
0.00 -10.00V
Actual
*
d02.09
AO2 output
0.00 -10.00V
Actual
*
d03: Running Status Parameters, on pages 45 - 46
d03.00
Heatsink temperature
0.0 - 999.9
℃
Actual
*
d03.01
Input terminal status
Display in 16-bit binary:
Bit15 - Bit12 Unused
Bit11 - Bit0 correspond to DI12 -
DI1
0: Disconnects with common
terminal
Actual
*