Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
HD3L Series Controller User Manual
―
49
―
6.2.4
F03: Acc / Dec Parameters
Ref. Code
Function Description
Setting Range [Default]
F03.00
Acc speed
0.020 - 9.999 [0.700m/s
2
]
F03.01
Start Acc jerk
0.020 - 9.999 [0.350m/s
3
]
F03.02
End Acc jerk
0.020 - 9.999 [0.600m/s
3
]
F03.03
Dec speed
0.020 - 9.999 [0.700m/s
2
]
F03.04
Start Dec jerk
0.020 - 9.999 [0.600m/s
3
]
F03.05
End Dec jerk
0.020 - 9.999 [0.350m/s
3
]
F03.00 - F03.05 adjust the elevator speed via S-curve which can cushion the shock at elevator start / stop
and improve riding comfort.
•
Acc jerk: The change ratio of Acc.
•
See the right figure for the adjustment of S-curve.
•
The S-curve becomes steeper when parameter
values are raised;
•
The S-curve becomes slower when parameter
values are decreased.
F03.06
Inspection Acc speed
0.020 - 9.999 [0.200m/s
2
]
Defines the Acc speed of elevator at inspection run mode.
F03.07
Inspection Dec speed
0.020 - 9.999 [1.000m/s
2
]
Defines the Dec speed of elevator at inspection run mode.
F03.08
Battery driven Acc speed
0.020 - 9.999 [1.000m/s
2
]
Defines the Acc speed of elevator at battery driven mode.
F03.09
Battery driven Dec speed
0.020 - 9.999 [1.000m/s
2
]
Defines the Dec speed of elevator at battery driven mode.
F03.10
Motor auto-tuning Acc speed
0.020 - 9.999 [0.100m/s
2
]
Defines the Acc speed at auto-tuning of the motor.
F03.11
Motor auto-tuning Dec speed
0.020 - 9.999 [0.100m/s
2
]
Defines the Dec speed at auto-tuning of the motor.
F03.12
Abnormal Dec speed
0.020 - 9.999 [1.000m/s
2
]
Defines the Dec speed at valid forced dec or wrong run mode.
F03.13
Stop Dec jerk
0.020 - 9.999 [0.350m/s
3
]
Defines dec change rate from non-zero speed to zero speed.
•
It can adjust the smooth stop of the elevator and add riding comfort.
F03.14 - F03.20 Unused
0
Speed
Target
speed
Time
F03.02
F03.04
F03.01
F03.05
F03.00
F03.03
F03.13
6