You can create a history control entry successfully even if the specified bucket size exceeds the
available history table size. RMON will set the bucket size as closely to the expected bucket size as
possible.
To create an RMON history control entry:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Ethernet
interface view.
interface interface-type
interface-number
N/A
3.
Create an RMON
history control entry.
rmon history
entry
-
number
buckets
number
interval
interval
[
owner
text
]
By default, no RMON history control
entries exist.
You can create multiple RMON history
control entries for an Ethernet interface.
You can create a maximum of 100
RMON history control entries on a
device. When the limit is reached, you
cannot add new entries.
Configuring the RMON alarm function
When you configure the RMON alarm function, follow these guidelines:
•
To send notifications to the NMS when an alarm is triggered, configure the SNMP agent as
described in "
" before configuring the RMON alarm function.
•
For a new event, alarm, or private alarm entry to be created:
The entry must not have the same set of parameters as an existing entry.
The maximum number of entries is not reached.
shows the parameters to be compared for duplication and the entry limits.
Table 8
RMON configuration restrictions
Entry
Parameters to be compared
Maximum number
of entries
Event
•
Event description (
description
string
)
•
Event type (
log
,
trap
,
logtrap
, or
none
)
•
Community name (
security-string
)
60
Alarm
•
Alarm variable (
alarm-variable
)
•
Sampling interval (
sampling-interval
)
•
Sample type (
absolute
or
delta
)
•
Rising threshold (
threshold-value1
)
•
Falling threshold (
threshold-value2
)
60
Private alarm
•
Alarm variable formula (
prialarm-formula
)
•
Sampling interval (
sampling-interval
)
•
Sample type (
absolute
or
delta
)
•
Rising threshold (
threshold-value1
)
•
Falling threshold (
threshold-value2
)
50
To configure the RMON alarm function: