For additional information about EVA maximums, see the
HP StorageWorks Enterprise Virtual Array
compatibility reference
.
A LUN presentation is the number of hosts presented to, regardless of how many adapters are in each
host.
For example, if a LUN is presented to eight hosts, that LUN has eight LUN presentations. If a LUN is
presented to two hosts, that LUN has two LUN presentations.
= 0256 LUN presentations
nl
= 0256 LUN presentations
nl
= 0256 LUN presentations
nl
= 0256 LUN presentations
nl
= 0256 LUN presentations
nl
= 0128 LUN presentations
nl
= 0008 LUN presentations
LUNs #001 through #032 are presented to 8-node cluster
nl
LUNs #033 through #064 are presented to 8-node cluster
nl
LUNs #065 through #096 are presented to 8-node cluster
nl
LUNs #097 through #128 are presented to 8-node cluster
nl
LUNs #129 through #160 are presented to 8-node cluster
nl
LUNs #161 through #192 are presented to 4-node cluster
nl
LUNs #193 through #200 are presented to single host
When all LUNs are presented to all hosts, the number of LUNs multiplied by the number of hosts must
not exceed 8,192.
Table 129
lists the maximum number of EVA storage systems that can be configured on a single server. There
is no limit on the maximum number of EVA storage systems in a SAN.
Table 129 EVA single-server maximum configurations
LUNs per HBA target
3, 4
EVA storage systems per HBA
3
Operating systems
1, 2
Storage systems
255
64
Tru64 UNIX
EVA3000/5000
EVA4000/4100
EVA6000/6100
EVA8000/8100
255
16
IBM AIX
255
8
NAS EFS Clustered
Gateway - Linux Edition
SUSE SLES 9
64
8
NAS EFS Clustered
Gateway - Windows
Edition Windows
nl
Storage Server 2003
128
16
Novell NetWare
256 (per server)
15
VMware ESX 3.
x
5
128 (per server)
15
VMware ESX 2.5.
x
5
255
32
HP-UX
EVA3000/5000
EVA4000/4100/4400
EVA5000
EVA6000/6100
EVA8000/8100
255
16
Linux (2.6 kernel)
128
16
Linux (2.4 kernel)
255
32
OpenVMS
255
16
Sun Solaris
255 (per server)
16
Windows 2000
Windows 2003
Windows 2008
EVA storage system rules
252
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...