![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Reference Manual Download Page 258](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108258.webp)
Cabling
This section describes cabling options for high-availability multipathing configurations for EVA storage
systems.
Level 4 NSPOF configuration
Figure 67
through
Figure 71
show cabling options when implementing a level 4, high-availability,
NSPOF configuration. For a description of availability levels, see “
Data availability
” on page 53.
Figure 67
shows the physical connections for a cross-cable, high-availability NSPOF configuration
for EVA3000/5000 VCS 3
x
storage systems using two separate fabrics. This cabling is the same
cabling scheme used for HP Continuous Access EVA. You can upgrade to an HP Continuous Access
EVA solution without needing to re-cable controller connections.
The cross-cable configuration shown in
Figure 67
is also supported for non-HP Continuous Access
EVA storage systems with VCS 3.
x
.
25129b
Figure 67 EVA3000/5000 VCS 3x cross-cable configuration
.
Figure 68
shows the physical connections for a straight-cable, high-availability NSPOF configuration
for EVA4000/4100/6000/6100 and EVA3000/5000 VCS 4
x
storage systems. This cabling scheme
supports non-HP Continuous Access EVA configurations and HP Continuous Access EVA configurations
with EVA4000/4100/6000/6100 and EVA3000/5000 VCS 4
x
storage systems. This configuration
is not supported with HP Continuous Access EVA for EVA3000/5000 VCS 3
x
storage systems.
EVA storage system rules
258
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...