NOTE:
Consider the following VIO requirements:
•
For NS1000 and NS1200 servers, expanded ports are available only to customers who have the
HP ESS.
•
The VIO enclosure software is not backward compatible and is supported only on H06.08 and
later RVUs.
•
Prior to December 2006, the NS1000 and NS14000 servers were shipped with a limited IOAME
configuration known as the IO Core, which consisted of an IOAME with six adapter slots rather
than the usual ten slots. Customer installations with the IO Core configuration will be supported
until December 2011.
Table 91
describes supported NonStop server configurations with IOAMEs.
Table 91 NonStop high-availability configurations using IOAMEs
Maximum availability config-
uration minimum/recommen-
ded
SAN configuration minim-
um/recommended
Direct host attach configura-
tion minimum/recommended
NonStop server support
2/4
2/2
0/0
Number of Fibre Channel SAN
fabrics
1/2
1/1
1/1
Number of XP storage systems
2/2
1/1
1/1
Number of IOAMEs
4/4
2/4
2/4
Number of Fibre Channel
ServerNet adapters
Table 92
describes supported NonStop server configurations with VIO enclosures.
Table 92 NonStop high-availability configurations using VIO enclosures (NS1000, NS1200, NS14000, and
NS14200 only)
Maximum availability config-
uration minimum/recommen-
ded
SAN configuration minim-
um/recommended
Direct host attach configura-
tion minimum/recommended
NonStop server support
2/4
2/2
0/0
Number of Fibre Channel SAN
fabrics
1/2
1/1
1/1
Number of XP storage systems
2/2
2/2
2/2
Number of VIO enclosures per
server
2/2
1/2
1/2
Number of 4-port Fibre Chan-
nel PICs per VIO enclosure
Table 93
describes supported NonStop BladeSystem with XP configurations using CLIMs.
SAN Design Reference Guide
199
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...