Switch type
Switching module
MDS 9513
nl
with Fabric-2
Modules
MDS 9513
nl
with Fabric-1
Modules
MDS 9509
nl
with
nl
Supervisor-2
Modules
MDS 9506
nl
with
nl
Supervisor-2
Modules
MDS 9222i
MDS 9216i
Yes
No
Yes
Yes
No
No
48-port 8Gb Performance
Fibre Channel Switching
Module
nl
(2 Gb, 4 Gb, 8 Gb)
Yes
No
Yes
Yes
No
No
24-port 8Gb Fibre Channel
Switching Module
nl
(2 Gb, 4 Gb, 8 Gb)
NOTE:
The MDS 9020, 9120, 9140, 9124, 9134, and 9124e switches have fixed configurations and do
not support additional switching modules.
NOTE:
The MDS 9513 requires Fabric-2 Modules to support the 48-port 8 Gb/s Performance Fibre Channel
Switching Module and the 24-port 8 Gb/s Fibre Channel Switching Module. Fabric modules are also
known as crossbar modules.
Features
Features of the C-series Fibre Channel switches include:
•
Nonblocking architecture using VOQ
•
VSAN deployment over the physical infrastructure
VSANs are separate instances of all fabric services, including address space.
•
Advanced diagnostics and troubleshooting (FC Ping, FC Traceroute, SPAN, RSPAN, and Call
Home)
•
Comprehensive security (SSH, SFTP, RADIUS, SNMPv3, and RBAC)
•
Comprehensive fabric management (CLI, SNMP, and Java-based GUI)
•
Traffic management (FCC and QoS)
•
High-availability, fault-tolerant software
•
PortChannel (ISL aggregation for highly resilient SAN architectures)
•
Integrated Multiprotocol capability (MDS 95
nn
and 92
nn
) for SAN extension (FCIP and iSCSI)
•
NPV—The following C-series Fibre Channel switches are NPV compliant: MDS 9124, MDS 9134,
and MDS 9124e. NPV requires SAN-OS 3.2(1a) or later. See
“
SAN fabric connectivity and switch interoperability rules
” on page 167.
•
FlexAttach virtual pWWN
The Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem, MDS 9124 switch, and MDS
9134 switch support NPV with FlexAttach. FlexAttach provides automatic mapping of physical
C-series switches and fabric rules
142
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...