background image

tams 

elektronik

 

 

 

 

 

 

 

Booster-Link

 

mfx

®

-Adapter für Booster

 

 

mfx

®

 adapter for booster

 

 

 

Adaptateur mfx

®

 pour 

 

 

mfx

®

-adapter voor boosters 

 

 

 

Anleitung 

 

 

Manual

 

 

Mode d´emploi

 

 

 

Handleiding

 

 

 

 

Art.-Nr. 49-02105 / 49-02106 / 49-02107  

 

 

 

 

Summary of Contents for mfx 49-02105

Page 1: ... s e l e k t r o n i k Booster Link mfx Adapter für Booster mfx adapter for booster Adaptateur mfx pour mfx adapter voor boosters Anleitung Manual Mode d emploi Handleiding Art Nr 49 02105 49 02106 49 02107 ...

Page 2: ...riting from Tams Elektronik GmbH Subject to technical modification 01 2016 Tams Elektronik GmbH Tout droits réservés en particulier les droits de reproduction et de diffusion ainsi que le traduction Toute duplication ou reproduction sous quelque forme que ce soit nécessite l accord écrit de la societé Tams Elektronik GmbH Sous réserve de modifications techniques 01 2016 Tams Elektronik GmbH Alle r...

Page 3: ...r Link 28 8 Check list for troubleshooting 28 9 CE and Warranty 29 Parts list I Printed Circuit Board PCB layout fig 1 II Circuit diagram fig 2 II Connections diagram fig 3 and pin connections III IV Pages I to IV in the centre of this handbook are removeable The asterisks This manual mentions the following company Gebr MÄRKLIN Cie GmbH Postfach 860 D 73008 Göppingen mfx RailCom is the registered ...

Page 4: ...future If you pass the kit or the ready built module on to another person please pass on the manual with it Intended use The Booster Link is designed to be operated according to the instructions in this manual with a digital model railway controlled by an mfx central unit Any other use is inappropriate and invalidates any guarantees The kit and the module should not be assembled or fitted by child...

Page 5: ...mall side cutter and wire stripper a pair of tweezers and long nose pliers tin solder 0 5 mm diameter In order to connect the module you need wire Recommended diameters 0 14 mm for the connections to the rails 2 Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries Watch out for sharp edges when you pick up the PCB Visibly damaged parts can cause unpre...

Page 6: ... hours for dispersion Use only original spare parts if you have to repair the kit or the ready built module Fire risk Touching flammable material with a hot soldering iron can cause fire which can result in injury or death through burns or suffocation Connect your soldering iron or soldering station only when actually needed Always keep the soldering iron away from inflammable materials Use a suit...

Page 7: ... and workshops assembly must be supervised by qualified personnel In industrial institutions health and safety regulations applying to electronic work must be adhered to 3 Safe and correct soldering Caution Incorrect soldering can cause dangers through fires and heat Avoid these dangers by reading and following the directions given in the chapter Safety instructions Use a small soldering iron with...

Page 8: ...the solder flows into the joint then remove the soldering iron Do not move the component for about 5 seconds after soldering To make a good soldering joint you must use a clean and unoxidised soldering tip Clean the soldering tip with a damp piece of cloth a damp sponge or a piece of silicon cloth Cut the wires after soldering directly above the PCB solder side with a side cutter After placing the...

Page 9: ...with commercial standard boosters and transfers the mfx feed back data across the isolation between the booster sections In layouts supplied by several boosters you need one Booster Link for each booster As usual in 3 rail systems the centre conductor has to be isolated between the booster sections when installing the Booster Link The outer conductors must not be isolated 5 Technical specification...

Page 10: ... Every colour stands for another figure The colour ring in brackets indicates the tolerance of the resistor which here is of no importance Value Colour rings 120 Ω brown red brown gold 470 Ω yellow violet brown gold 2 7 kΩ red violet red gold 3 3 kΩ orange orange red gold 47 kΩ yellow violet orange gold 330 kΩ orange orange yellow gold Diodes Diodes allow the current to pass through in one directi...

Page 11: ...apacitors are often used to store energy In contrast to ceramic capacitors they are polarized One of the two leads is marked with a minus sign which indicates the mounting orientation The value is given on the casing Electrolytic capacitors are available with different voltage sustaining capabilities Using an electrolytic capacitor with a voltage sustaining capability higher than required is alway...

Page 12: ... must lie on top of each other after mounting Micro Controler Micro controllers are ICs which are individually programmed for the particular application When leaving the manufacturer their memories are empty The programed controllers are normally only available from the circuit manufacturer Terminal strips Terminal strips are solder in screw type terminals They provide a solder free and safe conne...

Page 13: ...thout first discharging yourself by touching a radiator or other grounded metal parts Do not bend the legs of the ICs when inserting them into the sockets Check that the markings on the PCB the socket and the IC show to the same direction Performing a visual check Perform a visual check after the assembly of the module and remove faults if necessary Remove all loose parts wire ends or drops of sol...

Page 14: ...st for troubleshooting Parts are getting too hot and or start to smoke Switch off the digital system immediately Possible cause one or more components are soldered incorrectly In case you have mounted the module from a kit perform a visual check section 6 and if necessary remedy the faults Otherwise send in the module for repair The mfx central unit does not display the feedback data of the decode...

Page 15: ...es mentioned below and is therefore CE certified 2004 108 EG on electromagnetic Underlying standards EN 55014 1 and EN 61000 6 3 To guarantee the electromagnetic tolerance in operation you must take the following precautions Connect the transformer only to an approved mains socket installed by an authorised electrician Make no changes to the original parts and accurately follow the instructions co...

Page 16: ...orrection of faults which can be proved to be due to material failure or factory flaw With kits we guarantee the completeness and quality of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and the ready built circuit connected according to the manual and w...

Page 17: ... D5 D6 D7 1N400x x 2 7 Zenerdioden Zener diodes Diodes Zener Zenerdiode s D2 D3 ZD 15 V Kondensatoren Capacitors Condensateurs Condensatoren C8 C9 C10 C11 1 nF C5 10 nF C1 C2 C6 C7 100 nF Elkos Electrolytic capacitors Condens électrolytiques Elco s C3 C4 100µF Transistoren Transistors Transistors Transistors Q1 BD 679 ICs CI IC4 TL072P IC Sockel IC sockets Supports de CI IC voetjes IC4 8 pol Anrei...

Page 18: ...t a m s e l e k t r o n i k Booster Link Seite Page Page Pagina II Fig 1 Bestückungsplan PCB layout Plan d implantation Printplan Fig 2 Schaltplan Circuit diagram Schéma de principe Schakelschema ...

Page 19: ...er an den auch die Booster zur Versorgung der Anlage angeschlossen sind 3 Mittelleiter im Boosterabschnitt der über den in der Zentrale integrierten Booster versorgt wird Beachten Sie Verbinden Sie diesen Anschluss nicht mit dem Mittelleiter eines Boosterabschnittes der durch einen weiteren externen Booster versorgt wird Eine sichere Datenübertragung ist dann nicht gewährleistet Wenn der Booster d...

Page 20: ...2 Conducteur extérieur auquel sont connectés tous les amplis du réseau 3 Conducteur central du canton électrique alimenté par l ampli intégré de la centrale Attention ne reliez pas cette borne au conducteur central d un canton alimenté par un autre ampli externe la transmission des données en serait affectée Si l ampli de la centrale n est pas utilisé pour alimenter la voie reliez cette borne dire...

Page 21: ...rmations et conseils Actuele informatie en tips http www tams online de Garantie und Service Warranty and service Garantie et service Garantie en service Tams Elektronik GmbH Fuhrberger Straße 4 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de ...

Reviews: