•
Seamless, online, software and firmware upgrades
•
Selective storage presentation for SAN-based data zoning
•
Connectivity to Fibre Channel 2, 4, and 8 Gb/s switches
•
Support for up to sixteen 4-port arrays, eight 8-port arrays, or some other combination up to 64
ports
For more information, see the
HP StorageWorks SAN Virtualization Services Platform QuickSpecs
and
HP StorageWorks SAN Virtualization Services Platform design reference guide
, available for
download on the HP StorageWorks SAN Virtualization Services Platform website:
http://www.hp.com/go/SVSP
Software
HP SVSP software consists of the following:
•
HP StorageWorks SAN Virtualization Services Platform Business Copy for copies within an SVSP
domain
•
HP StorageWorks SAN Virtualization Services Platform Continuous Access for copies between
SVSP domains
•
HP StorageWorks SAN Virtualization Services Platform Thin Provisioning
•
HP StorageWorks SAN Virtualization Services Platform Volume Manager
•
HP StorageWorks Virtualization Services Manager (VSM)
•
HP StorageWorks Virtualization Services Manager Command Line Interface
The following operating systems are supported:
•
HP-UX 11i v2 and 11i v3
•
Red Hat Linux 4.0 and 5.0
•
SUSE Linux 10.0
•
Microsoft Windows Server 2003
•
Microsoft Windows 2008
•
Sun Solaris 10
•
VMware ESX 3.5, 3i
The following software is required:
•
Secure Path for HP-UX 11i v2
•
Native Multipath for HP-UX 11i v3
•
SAN Virtualization Services Platform DSM for Windows
For the latest product support information, see the product Quick Specs at http://www.hp.com/go/svsp
or SPOCK at:
http://www.hp.com/storage/spock
. You must sign up for an HP Passport to enable
access.
Hardware for a single SVSP domain
Hardware requirements are as follows:
•
Minimum of one EVA or MSA
•
High-availability dual-fabric environment (see
Level 4: multiple fabrics and device paths
(NSPOF)
on page 56)
•
IP-based intersite links (for SVSP Continuous Access)
SAN Virtualization Services Platform
272
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...