![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Reference Manual Download Page 254](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108254.webp)
NOTE:
The MPX200 data migration has a unique fan-in/fan-out licensing model. Using this particular
license, you can migrate data from multiple arrays to a single array or from a single array to
multiple arrays, three times; that is, this license can enable three different migration tasks using
the same MPX200 chassis at different times.
Table 130
describes the supported source and destination storage systems when using the MPX200
offline data migration feature. See the
HP StorageWorks MPX200 Multifunction Router User Guide
for information about configuring the MPX200 for offline data migration.
Table 130 Offline data migration source-destination storage systems
Destination storage systems
Source storage systems
•
EVA4400/4400 with embedded switch
•
EVA4000/4100/6000/6100/8000/8100
•
EVA6400/8400
•
All HP MSA (Fibre Channel) and EVA models
Third-party array models:
•
EMC CLARiiON AX series, CX Series
•
Hitachi Data Systems AMS Family, WMS Family
•
IBM DS4000 series, DS5000 series
For current data migration storage system support, see the SPOCK website at
http://www.hp.com/
storage/spock
. You must sign up for an HP Passport to enable access.
HP Continuous Access EVA SAN integration
HP Continuous Access EVA is supported in a heterogeneous SAN, provided that you follow the rules
described in
Table 131
.
Table 131 HP Continuous Access EVA heterogeneous SAN configuration rules
Description
Rule
nl
number
HP strongly recommends that all HP Continuous Access EVA deployments implement level 4 NSPOF
SANs using two or more separate fabrics. See “
Data availability
” on page 53.
HP Continuous Access EVA supports a subset of operating systems listed in this guide, which limits
the types of servers that can reside in the HP Continuous Access EVA management zone. For more
information, see the
HP StorageWorks Enterprise Virtual Array compatibility reference
matrix at
http://h18006.www1.hp.com/products/storage/software/conaccesseva/index.html
.
1
The maximum number of switches and switch hops supported in a fabric with HP Continuous Access
EVA is based on the limits for B-series, C-series, and M-series fabrics. All active and standby links
must conform to the switch hop limits, including the host-to-local storage link, the local storage-to-
remote storage link, and the local host-to-remote storage link. For more information, see the
HP
Continuous Access EVA planning guide
and the switch and fabric rules. For switch and fabric
rules, see:
•
“
B-series switches and fabric rules
” on page 93
•
“
C-series Fibre Channel and FCoE switches and fabric rules
” on page 135
•
“
M-series switches and fabric rules
” on page 157
2
EVA storage system rules
254
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...