NOTE:
HP does not recommend the ring fabric for applications requiring many-to-many connectivity.
25093a
Figure 5 Ring fabric
.
If the ring fabric has fewer than 12 switches, you can add switches (called satellite switches) outside
the ring to create more user ports (
Figure 6
). M-series switches have a 3-hop maximum, reducing the
total number of switches that can be configured in a ring to 7; satellite switches are not supported.
NOTE:
Adding satellite switches slightly reduces fabric availability.
For more information on switch fabric maximums, see:
•
“
H-series switches and fabric rules
” on page 83
•
“
B-series switches and fabric rules
” on page 93
•
“
C-series Fibre Channel and FCoE switches and fabric rules
” on page 135
•
“
M-series switches and fabric rules
” on page 157