Hardware redundancy
NOTE:
For more information about high-availability configurations when using the HP B-series MP Routers
or C-series VSANs, see “
High-availability MP Router configurations
” on page 74.
Several factors affect SAN data availability:
•
Application software
•
Server operating systems
•
Server hardware
•
SAN fabric infrastructure
•
Primary and secondary storage
•
Number of switches
•
Number of ISLs
•
Number of paths between a server or clustered servers and the fabric
•
Number of storage controller paths in the fabric
Levels
This section describes the data availability levels.
Level 1: single connectivity fabric
Level 1 provides maximum connectivity but does not provide fabric resiliency or redundancy. Each
switch has one path to other switches in the fabric (
Figure 12
). Each server and storage system has
one path to the fabric.
25098a
Figure 12 Level 1: single connectivity fabric
.
Level 2: single resilient fabric
Level 2 provides fabric path redundancy by using multiple ISLs between switches (
Figure 13
). Each
server and storage system has one path to the fabric. If an ISL or switch port failure occurs, the switch
automatically reroutes data through an alternate fabric path and there is no interruption in server I/O
activity.
SAN fabric topologies
54
Summary of Contents for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Page 26: ......
Page 34: ...SAN design overview 34 ...
Page 60: ...SAN fabric topologies 60 ...
Page 80: ...Fibre Channel routing 80 ...
Page 82: ......
Page 92: ...H series switches and fabric rules 92 ...
Page 156: ...C series switches and fabric rules 156 ...
Page 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Page 184: ......
Page 270: ...XP and VA storage system rules 270 ...
Page 276: ...Enterprise Backup Solution 276 ...
Page 278: ......
Page 354: ...SAN extension 354 ...
Page 398: ...Network Attached Storage 398 ...
Page 400: ......
Page 416: ...Storage security 416 ...
Page 428: ...Best practices 428 ...
Page 456: ...456 ...