The 68VHDCI-50F SSR 8, 16, 24 Channel Cable Adapter allows you to
connect the digital I/O port of your National Instruments 7344, 7314, or
7324 series motion controller to a third-party SSR (solid-state relay)
backplane. National Instruments recommends using the SHC68-C68-S
cable (part number 186380-02) with this cable adapter.

Connecting Your Adapter

Do the following steps to connect your adapter:

1.

Make sure all computers and peripherals are turned off, unplugged,
and that all LED lights have gone out, since some hardware remains
internally powered for some time after being unplugged.

2.

Install the 50-pin connector of the adapter onto the backplane
connector. The connector is keyed and can only install one way.

3.

Connect the SHC68-C68-S cable from the digital I/O port of your
motion controller to the adapter.

4.

Verify the adapter switches are in the correct position for your
application. Refer to

Configuring Your Switches

in the

Adapter

Configuration

section of this guide for more information.

Summary of Contents for 68VHDCI-50F SSR 8

Page 1: ...truments recommends using the SHC68 C68 S cable part number 186380 02 with this cable adapter Connecting Your Adapter Do the following steps to connect your adapter 1 Make sure all computers and peripherals are turned off unplugged and that all LED lights have gone out since some hardware remains internally powered for some time after being unplugged 2 Install the 50 pin connector of the adapter o...

Page 2: ... Your Switches Your adapter has six switches labelled S1 through S6 that affect its behavior when used with a 7344 series motion controller If you are using a 7314 or 7324 series motion controller all six switches must be in the up position as shown in Figure 1 Figure 1 68VHDCI 50F SSR 8 16 24 Channel Cable Adapter Default Switch Settings The following is a description of each switch and its effec...

Page 3: ...res S4 PWMB Moving this switch to the down position connects the PWM1 output to module 6 This switch should remain in the up position for typical operation Refer to the 7344 Hardware User Manual for information on using PWM features S5 PCLK Moving this switch to the down position connects the PCLK output to module 5 This switch should remain in the up position for typical operation Refer to the 73...

Page 4: ...Module 18 Module 19 Module 20 Module 21 Module 22 Module 23 Module 2 5 V Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Ground Digital Grou...

Reviews: