106
Troubleshooting
Temperatur
e is over
limit
Critical
none
Critical
Temp is
>54.5º
C
A fan is faulty. Check status and
correct.
Airflow is obstructed; vents are
blocked.
One or more slots are empty.
Power supply is faulty. Check
status and correct.
Room temperature is too high. If
ambient temperature cannot be
reduced in a reasonable time, turn
off product to prevent shortened
life.
Temperature sensor is faulty.
Compare temperature reported by
peer BCC.
Major
Warning
none
Non-
critical
Temp is
>36º C
Temperature sensors are on the BCC and
are independent of power supplies.
Investigate temperature warnings
immediately, before power supplies sense
critical temperature and turn off.
Temperature
is under limit
Critical
none
Critical
Temps
<9.5º C
– Room temperature is too low.
– Temperature sensor is faulty.
Compare temperature reported by
peer BCC.
Major
Warning
none
Non-
critical
Temps
<15.5º C
Voltage is
over limit
Critical
none
Critical
Power supply is faulty. Check
status and correct.
Major
Warning
none
Non-
critical
Voltage is
under limit
Critical
none
Critical
Either power supply is faulty.
Check status and correct.
Major
Warning
none
Non-
critical
Peer BCC
status,
temperature
and voltage
are Not
Available
Major
Warning
none
Both
BCCs:
Non-
critical
Firmware on BCC A and BCC B are
different versions.
none
Not
Available
Internal bus is faulty. Contact HP
technical support to replace
midplane.
Table 12.
Troubleshooting Table (Continued)
Problem
Description
HW Event
Category
LED
State
STM
Status
Probable Cause/Solution
Summary of Contents for StorageWorks 2300 - Disk System
Page 1: ...hp StorageWorks disk system 2300 Edition E0902 user s guide ...
Page 10: ...10 ...
Page 14: ...14 Product Description ...
Page 35: ...Installation 35 Installation 2 ...
Page 40: ...40 Installation ...
Page 41: ...Installation 41 Installation ...
Page 48: ...48 Installation ...
Page 58: ...58 Installation ...
Page 59: ...Installation 59 Installation 4 Install clipnuts as shown in Figure 28 ...
Page 76: ...76 Installation ...
Page 77: ...Installation 77 Installation ...
Page 83: ...Configuration 83 Configuration 3 ...
Page 86: ...86 Configuration ...
Page 94: ...94 Configuration ...
Page 95: ...Troubleshooting 95 Troubleshooting 4 ...
Page 108: ...108 Removal and Replacement ...
Page 132: ......
Page 134: ......
Page 140: ......
Page 150: ...150 Reference E VCCI Statement Japan Harmonics Conformance Japan F BCIQ EMC Statement Taiwan ...
Page 151: ...Reference 151 Reference G Declaration of Conformity ...
Page 158: ...158 ...