Hardware options installation 86
•
If two fans fail, then the server shuts down.
IMPORTANT:
Fan louvers must be present for the redundant configuration. Without the louvers,
all four fans are nonredundant.
NOTE:
If your system is already installed with four fans, store the fan that is included in this kit as
a spare.
Installing a hot-plug redundant fan
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
21
).
o
For rack models, if installed, remove the security bezel (on page
21
).
2.
Power down the server (on page
20
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
24
).
5.
Remove the access panel (on page
23
).
6.
Remove all the fans and fan blanks.