Hardware options installation 65
Installing the six-bay LFF backplane (bay 1)
To install the component:
1.
Power down the server (on page
22
).
2.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Open or remove the tower bezel
" on page
22
).
o
Extend the server from the rack (on page
24
).
3.
Remove the access panel (on page
25
).
4.
Remove fan 5 (on page
26
).
5.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page
27
).
6.
Remove the air baffle (on page
28
).
7.
Remove the fan cage (on page
29
).
8.
Remove any SFF drives installed in bay 1.
9.
Disconnect the power and data cables from the eight-bay SFF drive cage in drive cage bay 1.
10.
Using a T-10 Torx screwdriver, remove the eight-bay SFF drive cage from drive cage bay 1.