Hardware options installation 99
IMPORTANT:
For the system to operate properly in a rack configuration, be sure to change the
setting on the system maintenance switch.
40.
Set position 3 on the system maintenance switch to On.
For the location of the system maintenance switch, see the label attached to the access panel.
41.
Install the access panel.
42.
Install the server in the rack.
See the instructions in the rack-mounting hardware kit.
43.
Install the following items:
o
Hard drives and blanks
o
Media blank
o
Power supplies
44.
Connect all rear panel cabling.
45.
Power up the server.
HP Trusted Platform Module option
Use these instructions to install and enable a TPM on a supported server. This procedure includes three
sections:
1.
Installing the Trusted Platform Module board (on page
100
).
2.
Retaining the recovery key/password (on page
101
).
3.
Enabling the Trusted Platform Module (on page
101
).
Enabling the TPM requires accessing the ROM-Based Setup Utility (RBSU) ("
HP ROM-Based Setup
Utility
" on page
116
). For more information about RBSU, see the HP website
(
http://www.hp.com/support/smartstart/documentation
).
TPM installation requires the use of drive encryption technology, such as the Microsoft® Windows®
BitLocker™ Drive Encryption feature. For more information on BitLocker™, see the Microsoft website
(
http://www.microsoft.com
).
CAUTION:
Always observe the guidelines in this document. Failure to follow these guidelines
can cause hardware damage or halt data access.
When installing or replacing a TPM, observe the following guidelines:
•
Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system
board.
•
When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption
technology. For security reasons, only the customer can enable these features.
•
When returning a system board for service replacement, do not remove the TPM from the system board.
When requested, HP Service provides a TPM with the spare system board.
•
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the
system compromised and take appropriate measures to ensure the integrity of the system data.
•
When using BitLocker™, always retain the recovery key/password. The recovery key/password is
required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.
Summary of Contents for ProLiant DL G6
Page 32: ...Operations 32 3 Remove the hard drive cage blank ...
Page 106: ...Cabling 106 Six bay LFF backplane cabling Drive cage bay 1 Drive cage bay 2 ...
Page 107: ...Cabling 107 Eight bay SFF drive cage cabling Drive cage bay 1 Drive cage bay 2 ...
Page 110: ...Cabling 110 DVD ROM drive cabling Slimline optical drive cabling ...
Page 115: ...Cabling 115 BBWC battery pack and FBWC capacitor pack cabling ...
Page 138: ...Troubleshooting 138 ...
Page 164: ...Technical support 164 ...
Page 165: ...Technical support 165 ...