Hardware options installation 52
•
Observe the general DIMM slot population guidelines (on page
50
).
•
DIMM configuration on each channel of a processor must be identical.
•
Each processor must have a valid Online Spare configuration.
•
In multi-processor configurations, each processor can have a different valid Online Spare
configuration.
Installing a DIMM
CAUTION:
To avoid damage to the hard drives, memory, and other system components, the air
baffle, drive blanks, and access panel must be installed when the server is powered up.
1.
Power down the server (on page
22
).
2.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Open or remove the tower bezel
" on page
22
).
o
Extend the server from the rack (on page
24
).
3.
Remove the access panel (on page
25
).
4.
Remove fan 5 (on page
26
).
5.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page
27
).
6.
Remove the air baffle (on page
28
).
7.
Open the DIMM slot latches.
8.
Install the DIMM.
9.
Install the air baffle.
10.
If removed, install the BBWC battery pack or the FBWC capacitor pack ("
Installing the BBWC battery
pack or the FBWC capacitor pack
" on page
86
).
11.
Install fan 5.
12.
Install the access panel.
If you are installing DIMMs in lock-step configuration, configure this mode in RBSU ("
HP ROM-Based Setup
Utility
" on page
116
).
Summary of Contents for ProLiant DL G6
Page 32: ...Operations 32 3 Remove the hard drive cage blank ...
Page 106: ...Cabling 106 Six bay LFF backplane cabling Drive cage bay 1 Drive cage bay 2 ...
Page 107: ...Cabling 107 Eight bay SFF drive cage cabling Drive cage bay 1 Drive cage bay 2 ...
Page 110: ...Cabling 110 DVD ROM drive cabling Slimline optical drive cabling ...
Page 115: ...Cabling 115 BBWC battery pack and FBWC capacitor pack cabling ...
Page 138: ...Troubleshooting 138 ...
Page 164: ...Technical support 164 ...
Page 165: ...Technical support 165 ...