Troubleshooting
Browser or Telnet Access Problems
Cannot Telnet into the switch console from a station on the network:
■
Telnet access may be disabled by the
Inbound Telnet Enabled
parameter in
the System Information screen of the menu interface:
2. Switch Configuration
1. System Information
■
The switch may not have the correct IP address, subnet mask, or gateway.
Verify by connecting a console to the switch’s Console port and selecting:
2. Switch Configuration
5. IP Configuration
Note:
If DHCP/Bootp is used to configure the switch, refer to the
Note
,
above.
■
If you are using DHCP to acquire the IP address for the switch, the IP
address “lease time” may have expired so that the IP address has changed.
For more information on how to “reserve” an IP address, refer to the
documentation for the DHCP application that you are using.
■
If one or more IP-Authorized managers are configured, the switch allows
inbound telnet access only to a device having an authorized IP address.
For more information on IP Authorized managers, refer to the
Access
Security Guide
for your switch.
C-7
Summary of Contents for PROCURVE 2520
Page 2: ......
Page 3: ...HP ProCurve 2520 Switches November 2009 S 14 03 Management and Configuration Guide ...
Page 60: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 82: ...Using the Command Line Interface CLI CLI Editing Shortcuts 4 22 ...
Page 146: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 40 ...
Page 164: ...Interface Access and System Information System Information 7 18 ...
Page 292: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 12 30 ...
Page 374: ...Configuring for Network Management Applications LLDP Link Layer Discovery Protocol 13 82 ...
Page 434: ...Monitoring and Analyzing Switch Operation Locating a Device B 30 ...
Page 514: ...Troubleshooting DNS Resolver C 80 ...
Page 524: ...Daylight Savings Time on ProCurve Switches E 4 ...
Page 542: ...16 Index ...
Page 543: ......