Power Over Ethernet (PoE) Operation
Configuring PoE Operation
ProCurve(config)# show power-over-ethernet 6
Status and Counters - Port Power Status for port 6
Power Enable : Yes
LLDP Detect : enabled
Priority
: low
Configured Type :
AllocateBy
: value
Value
: 15 W
Detection Status : Delivering Power Class
: 2
Maximum
power
delivered
Over Current Cnt : 0
MPS Absent Cnt
: 0
Power Denied Cnt : 0
Short Cnt
: 0
Voltage
: 49.1 V
Current : 154 mA
Power
: 8.4 W
Figure 11-2. Example Displaying PoE Allocation by Value and the Maximum Power Delivered
If you set the PoE maximum value to less than the PD requires, a fault occurs.
ProCurve(config)# int 7 poe-value 4
ProCurve(config)# show power-over-ethernet 7
Status and Counters - Port Power Status for port 7
Power Enable
: Yes
LLDP Detect : enabled
Priority : low
Configured Type
:
AllocateBy : value
Value
: 4 W
Detection Status : Other Fault Power Class
: 2
Over Current Cnt : 0
MPS Absent Cnt
: 0
Power Denied Cnt : 2
Short Cnt
: 0
Voltage : 49.1 V
Current
: 154 mA
Power
: 8.4 W
Figure 11-3. Example Showing PoE Power Value Set Too Low for the PD
11-12
Summary of Contents for PROCURVE 2520
Page 2: ......
Page 3: ...HP ProCurve 2520 Switches November 2009 S 14 03 Management and Configuration Guide ...
Page 60: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 82: ...Using the Command Line Interface CLI CLI Editing Shortcuts 4 22 ...
Page 146: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 40 ...
Page 164: ...Interface Access and System Information System Information 7 18 ...
Page 292: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 12 30 ...
Page 374: ...Configuring for Network Management Applications LLDP Link Layer Discovery Protocol 13 82 ...
Page 434: ...Monitoring and Analyzing Switch Operation Locating a Device B 30 ...
Page 514: ...Troubleshooting DNS Resolver C 80 ...
Page 524: ...Daylight Savings Time on ProCurve Switches E 4 ...
Page 542: ...16 Index ...
Page 543: ......