Time Protocols
SNTP: Viewing, Selecting, and Configuring
Enabling SNTP in Broadcast Mode.
Because the switch provides an SNTP
polling interval (default: 720 seconds), you need only these two commands
for minimal SNTP broadcast configuration:
Syntax:
timesync sntp
Selects SNTP as the time synchronization method
.
Syntax:
sntp broadcast
Configures
broadcast
as the SNTP mode
.
For example, suppose:
■
Time synchronization is in the factory-default configuration (TimeP
is the currently selected time synchronization method).
■
You want to:
1. View the current time synchronization.
2. Select SNTP as the time synchronization mode.
3. Enable SNTP for Broadcast mode.
4. View the SNTP configuration again to verify the configuration.
The commands and output would appear as follows:
ProCurve(config)# show sntp
1
show sntp
displays the SNTP configuration and also shows that
TimeP is the currently active time synchronization mode.
SNTP Configuration
Time Sync Mode: Timep
SNTP Mode : disabled
Poll Interval (sec) [720] : 720
ProCurve(config)# timesync sntp
ProCurve(config)# sntp broadcast
2
3
5406_1(config)# show sntp
4
show sntp
again displays the SNTP configuration and shows that
SNTP is now the currently active time synchronization mode and
SNTP Configuration
is configured for broadcast operation.
Time Sync Mode: Sntp
SNTP Mode : Broadcast
Poll Interval (sec) [720] : 720
Note:
The
Protocol Version
parameter will also appear in
show sntp
listings if the IP address of an SNTP server (used
in Unicast mode) is configured in the switch. However, the protocol version is used only when SNTP is configured
for Unicast operation. See “Enabling SNTP in Unicast Mode” on page 12.
Figure 9-7. Example of Enabling SNTP Operation in Broadcast Mode
9-11
Summary of Contents for PROCURVE 2520
Page 2: ......
Page 3: ...HP ProCurve 2520 Switches November 2009 S 14 03 Management and Configuration Guide ...
Page 60: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 82: ...Using the Command Line Interface CLI CLI Editing Shortcuts 4 22 ...
Page 146: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 40 ...
Page 164: ...Interface Access and System Information System Information 7 18 ...
Page 292: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 12 30 ...
Page 374: ...Configuring for Network Management Applications LLDP Link Layer Discovery Protocol 13 82 ...
Page 434: ...Monitoring and Analyzing Switch Operation Locating a Device B 30 ...
Page 514: ...Troubleshooting DNS Resolver C 80 ...
Page 524: ...Daylight Savings Time on ProCurve Switches E 4 ...
Page 542: ...16 Index ...
Page 543: ......