Power Over Ethernet (PoE) Operation
Configuring PoE Operation
Table 11-1. Power Classes and Their Values
Power Class
Value
0
Depends on cable type and PoE architecture. Maximum
power level output of 15.4 watts at the PSE.
This is the default class; if there isn’t enough information
about the load for a specific classification, the PSE
classifies the load as class 0 (zero).
1
Requires at least 4 watts at the PSE.
2
Requires at least 7 watts at the PSE.
3
15.4 watts
4
For PoE+
Maximum power level output of 30 watts at the PSE.
For example, to allocate by class for ports 6 - 8:
ProCurve(config)# int 6-8 PoE-allocate-by class
Manually Configuring PoE Power Levels
You can specify a power level (in watts) allocated for a port by using the
value
option. This is the maximum amount of power that will be delivered.
To configure a port by value, first set the PoE allocation by entering the
poe
allocate-by value
command:
ProCurve(config)# int 6 poe-allocate-by value
or in interface context:
ProCurve(eth-6)# poe-allocate-by value
Then select a value:
ProCurve(config)# int 6 poe-value 15
or in interface context:
ProCurve(eth-6)# poe-value 15
To view the settings, enter the
show power-over-ethernet
command:
11-11
Summary of Contents for PROCURVE 2520
Page 2: ......
Page 3: ...HP ProCurve 2520 Switches November 2009 S 14 03 Management and Configuration Guide ...
Page 60: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 82: ...Using the Command Line Interface CLI CLI Editing Shortcuts 4 22 ...
Page 146: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 40 ...
Page 164: ...Interface Access and System Information System Information 7 18 ...
Page 292: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 12 30 ...
Page 374: ...Configuring for Network Management Applications LLDP Link Layer Discovery Protocol 13 82 ...
Page 434: ...Monitoring and Analyzing Switch Operation Locating a Device B 30 ...
Page 514: ...Troubleshooting DNS Resolver C 80 ...
Page 524: ...Daylight Savings Time on ProCurve Switches E 4 ...
Page 542: ...16 Index ...
Page 543: ......