2 Site preparation
The HP Integrity BL860c i2 Server Blade does not have cooling or power systems. Cooling and
power is provided by the c-Class enclosure.
IMPORTANT:
To avoid hardware damage, allow the thermal mass of the product to equalize to
the temperature and humidity of the installation facility after removing the shipping materials. A
minimum of one hour per 10°C (18°F) of temperature difference between the shipping facility and
installation facility is required
Server blade dimensions and weight
Table 1 Server blade dimensions and weight for the BL860c i2
value
Dimensions
36.63 cm (14.42 in.)
Height
5.14 cm (2.025 in.)
Width
48.51 cm (19.1 in.)
Depth
Unloaded: 8.6 kg (19 lb)
Fully loaded: 11.3 kg (25 lb)
Weight
Table 2 Blade Link dimensions and weight
Weight
Width
Height
Blade Link type
.5 lb (.22 kg)
51 mm (2 in)
44 mm (1.73 in)
SBL1 (BL860 i2)
1 lb (.45 kg)
106 mm (4.17 in)
44 mm (1.73 in)
SBL2 (BL870 i2)
2 lb (.90 kg)
212 mm (8.34 in)
44 mm (1.73 in)
SBL4 (BL890 i2)
Enclosure information
All three blade configurations are supported in c7000 and c3000 Enclosures.
For more enclosure information see:
http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0-121.html
.
Enclosure environmental specifications
NOTE:
This information is for both c3000 and c7000 Enclosures.
Value
Specification
Temperature range
1
10°C to 35°C (50°F to 95°F)
Operating
-30°C to 60°C (-22°F to 140°F)
Non-operating
Wet bulb temperature
28ºC (82.4ºF)
Operating
38.7ºC (101.7ºF)
Non-operating
Relative humidity (noncondensing)
2
10
Site preparation