NOTE:
The mounting bracket is installed either on top of a mezzanine card in slot 1, or the
mezzanine blank in slot 1, depending upon the customer's configuration. If no card is used in slot
1, the mezzanine card blank must be installed for the bracket to clip onto.
NOTE:
The Supercap Pack includes two plastic tabs that must be removed for proper fit in the
BL860c i2, BL870c i2, and BL890c i2 server blades. One tab is located on the rounded end of
the Supercap Pack, the other tab is directly above the cable as it exits the plastic housing of the
Supercap Pack. To remove these tabs, squeeze them firmly toward each other (significant force is
required). Optionally, these two tabs can be clipped off even with the rest of the Supercap Pack.
1.
Position the Supercap Pack with the print side down and push the end of the cable that is
connected to the Supercap Pack under the mounting bracket’s C-hook, routing the cable so
its supercap end is on the side of the hook that is away from slot 3
2.
Push the other end of the Supercap Pack down between the two restraining clips.
3.
Consolidate and secure remaining cable length using tie wrap or similar retention method.
Replacing the access panel
1.
Place the access panel onto the server blade by lining up the keyways on the panel to the
posts on the server blade chassis.
2.
Slide the access panel toward the front of the server blade until the panel lock button snaps
into place.
Installing internal components
65