a.
Log into the Monarch iLO 3 MP, enter the Command Menu, and execute the command
sysset
. This will list the system information parameters stored in the Upgrade Blade Link
(Primary) and those stored on the server blade (Secondary). Below is an example of the
output when upgrading from a BL860c i2 to a BL870c i2.
[ilo002264fee1be] CM:hpiLO-> sysset
SYSSET
Current System Information Parameters:
Manufacturer : HP
Product Name (prodname) : Integrity BL870c i2
Secondary Product Name : Integrity BL860c i2
Product Number (prodnum) : AM358A
Secondary Product Number : AD399A
Serial number (serial) : Uninitialized
Secondary Serial Number : USA0003
UUID (uuid) : FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF
Secondary UUID : 89742B3C-AD78-11DF-BB2A-5ABBD7A51B74
Product ID : 0x702
An Upgrade Blade Link has been detected.
Primary and secondary system parameters values do not match.
Copy secondary UUID and serial number to primary? (Y/[N]):
The product name and product number from the Upgrade Blade Link reflect a BL870c
i2, while the Secondary product name and number (from the Monarch Server) reflect the
original BL860c i2.
b.
The system detects the Upgrade Blade Link and prompts you to make the required system
information exchanges between Upgrade Blade Link and the server. Enter
y
to approve
the exchange. You will then be informed that a reset of the iLO 3 MP is necessary for the
changes to take effect.
Copy secondary UUID and serial number to primary? (Y/[N]): y
-> Secondary system parameters values have been copied to primary
system parameters.
->System Information parameters have been updated.
iLO MP needs to be reset in order for these changes to take effect
c.
Reset the iLO 3 MP by entering
xd –r –nc
at the Command Menu prompt.
[ilo002264fee1be] CM:hpiLO-> xd -r -nc
XD -r -nc
-> MP reset requested
MP is now being reset...
-> Command successful.
Installing internal components
77