4
3
1
Mezzanine foot
C-hook
Cable restraining clips
2
Mezzanine post loop
Installing the Supercap mounting bracket
1.
Power off the server blade and remove it from the server blade enclosure (
“Preparing the
server blade for servicing”
).
2.
Remove the access panel (
“Access panel” (page 113)
).
3.
Remove the DIMM baffle (
“DIMM baffle” (page 115)
)
4.
Temporarily remove any mezzanine card installed in slot 2 (
“Mezzanine cards” (page 123)
).
NOTE:
Mezzanine slot 1 must contain the P711m Controller, another mezzanine card, or
the mezzanine card blank. If you are installing the P711m card in mezzanine slot 1, do so
now following the instructions “Installing the P711m Controller Board.” If you are not installing
the P711m card in mezzanine slot 1, and no other mezzanine card is present in slot 1, then
install the mezzanine card blank at this time.
5.
Clip the mounting bracket onto the mezzanine card or mezzanine card blank.
6.
Press the bracket thumbscrew clip over the thumbscrew closest to the mezzanine post.
7.
Push the remaining bracket foot over the other edge of the mezzanine card or mezzanine
card blank.
CAUTION:
Push only enough to anchor the bracket, keeping the bracket level.
CAUTION:
To avoid damage to the power cable ensure the battery bracket does not pinch
the power cable to the power connectors.
Installing internal components