Error messages 112
1615-Power Supply Configuration Error
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is
displayed, indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is
displayed, indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure in Bay X
Audible Beeps
: None
Possible Cause
: The power supply has failed, or it is installed but not connected to the system board or
AC power source.
Action
: Reseat the power supply firmly and check the power cable or replace power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps
: None
Possible Cause
: Power supply is improperly configured.
Action
: Run the server setup utility and correct the configuration.
1700 Series
1711-Slot Z Drive Array - RAID ADG Logical Drive(s) Configured but Array Accelerator Size <=
32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 5 or upgrading the Array
Accelerator module.
Audible Beeps
: None
Possible Cause
: This configuration is not recommended.
Action
: Migrate logical drives to RAID 5 or upgrade to a larger array accelerator module.
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but Array
Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number
of drives in the array, or upgrading the Array Accelerator module.