I. COMPONENT INSTALLATION:
INSTALLATION CAUTIONS:
Do not over tighten PVC fittings. If threaded pipe
fittings leak after installation then remove the
fitting, clean the male mating threads, apply 3 to 4
wraps of Teflon tape to the male threads and then
thread the parts back together.
The Inlet Connection [1], Sea Strainer [3], Inlet
Clean/Rinse Valve [4] and Booster Pump [5] must
be mounted below water level to operate properly.
REMOVE ALL TUBE SHIPPING PLUGS
FROM THE RIGHT SIDE OF THE HORIZON
SEAFARI
.
Always use 2 supplied Hose Clamps at each
connection to secure the hose to its respective Hose
Barb Fitting and seal it from leaks.
Always allow the tube to enter and exit straight
from the tube fitting for a minimum of one inch
prior to starting a bend.
DO NOT
tie or tee the Horizon Seafari System
Feed Line into another line that already feeds
another auxiliary system.
DO NOT
tie or tee another auxiliary system into
the Horizon Seafari System Feed Line.
DO NOT
mount the R.O. Membrane assembly in
areas with temperatures above 120
°
F / 40 C or in
freezing temperatures. Do not mount the MVA in
areas exposed to radiant heat above 120
°
F / 40 C.
Avoid skin and eye contact with the storage
solution the membrane is packaged in. In case of
skin contact, rinse the skin thoroughly with water.
In case of eye contact, flush repeatedly with water
and notify a physician immediately.
1.
Inlet Thru Hull Fitting [1] with Inlet Sea Cock
Valve
[2]
The Sea Cock Valve [2] must be fitted with 3/4"
MNPT (Male National Pipe Taper, i.e. American
Standard Tapered Pipe Thread) at the Sea Cock
Valve’s outlet.
The Thru Hull Fitting must be located well below
the water line so the inlet remains in constant
contact with the feed water even while vessel is
under way.
Remove Plug from Brine
Discharge Fitting
Remove Plug From Product
Outlet Fitting
NOTE:
ON THE REAR OF THE CONTROL
MANIFOLD THERE IS A PIGTAIL WHICH IS
CONNECTED TO THE LOW PRESSURE
GAUGE. CONNECT THIS PIGTAIL TO THE
OUTLET OF THE FINAL FILTER PRIOR TO
THE HIGH PRESSURE PUMP.
Page E - 11
Summary of Contents for Seafari Versatile SFC-1400-2
Page 7: ...HROSystems Horizon Seafari Self Contained and Modular Style NOTES vi...
Page 8: ...SECTION A WARRANTY...
Page 10: ...HRO Systems Horizon Seafari Self Contained and Modular Style Page A 2 NOTES...
Page 11: ...SECTION B SPECIFICATIONS...
Page 17: ...HROSystems Horizon Seafari Self Contained and Modular Style NOTES Page B 6...
Page 18: ...SECTION C INTRODUCTIONS...
Page 22: ...HROSystems Horizon Seafari Self Contained and Modular Style Page C 4 NOTES...
Page 23: ...SECTION D SYSTEM SCHEMATIC WITH COMPONENT IDENTIFICATIONS COMPONENT DESCRIPTIONS...
Page 31: ...HROSystems Horizon Seafari Self Contained and Modular Style Page D 8 NOTES...
Page 32: ...SECTION E SYSTEM INSTALLATION PROCEDURE...
Page 61: ...HROSystems Horizon Seafari Self Contained and Modular Style Page F 10 NOTES...
Page 63: ...HROSystems Horizon Seafari Self Contained and Modular Style Page F 12 NOTES...
Page 64: ...SECTION G SYSTEM START UP PROCEDURE...
Page 69: ...HROSystems Horizon Seafari Section G System Start Up Procedure Page G 5...
Page 70: ...SECTION H SHUTDOWN PROCEDURE...
Page 74: ...SECTION I SYSTEM TROUBLESHOOTING GUIDE...
Page 90: ...HROSystems Horizon Seafari Self Contained and Modular Style Page I 16...
Page 114: ...SECTION L EXPLODED PARTS VIEWS WITH DESCRIPTION PART NUMBERS...
Page 135: ...APPENDIX A WIRING INFORMATION DIAGRAMS...
Page 148: ...APPENDIX B...
Page 156: ...HROSystems Horizon Seafari Self Contained and Modular Style APPENDIX B 8 NOTES NOTES...