“Section D” System Schematic with Component Identification & Descriptions
Page D - 7
2. INDICATOR LAMPS
Above and to the left of the
switches on the Touch Pad are the indicator lamps.
These lamps either indicate the operation of the
corresponding equipment or a fault condition. The
following are descriptions of the indicator lamps.
G. OPTIONAL EQUIPMENT
Soft Start***
The soft start lowers the starting
torque of the high-pressure pump motor, and
gradually brings the motor to full speed. This
reduces the initial startup amps required to start the
motor. The soft start is available on single-phase
systems and allows starting of the system when the
power/source, i.e. generator, is marginal or
insufficient to start the system un-assisted. By
reducing the starting torque of the motor, the system
demands lower initial power at startup and can
operate on an otherwise insufficient power source.
Power:
This indicator is lit when power is
supplied to the controller. This indicates that the
main power breaker has been switched on.
System On:
This lamp illuminates when the
High Pressure Pump is operating.
Booster Pump:
This lamp illuminates when the
booster pump is operating.
Fresh Water Flush:
This indicator illuminates
solidly during the Fresh Water Flushing
operation. When the Fresh Water Flush is
between the ten minute flushings, which repeat
every seven days, this lamp blinks on and off.
Water Quality:
This lamp indicates the quality
of the water being produced by the system. A
red lamp illuminates when the system is
producing un-potable water. A green lamp
illuminates when the system is producing potable
water.
High/Low Pressure:
The High/Low pressure
fault lamp illuminates when the system shuts
down due to either a low-pressure condition, or a
high-pressure condition. If the Low Pressure
Switch senses a low-pressure condition, this
lamp blinks for twenty seconds, and then the
system shuts down.
Summary of Contents for Seafari Versatile SFC-1400-2
Page 7: ...HROSystems Horizon Seafari Self Contained and Modular Style NOTES vi...
Page 8: ...SECTION A WARRANTY...
Page 10: ...HRO Systems Horizon Seafari Self Contained and Modular Style Page A 2 NOTES...
Page 11: ...SECTION B SPECIFICATIONS...
Page 17: ...HROSystems Horizon Seafari Self Contained and Modular Style NOTES Page B 6...
Page 18: ...SECTION C INTRODUCTIONS...
Page 22: ...HROSystems Horizon Seafari Self Contained and Modular Style Page C 4 NOTES...
Page 23: ...SECTION D SYSTEM SCHEMATIC WITH COMPONENT IDENTIFICATIONS COMPONENT DESCRIPTIONS...
Page 31: ...HROSystems Horizon Seafari Self Contained and Modular Style Page D 8 NOTES...
Page 32: ...SECTION E SYSTEM INSTALLATION PROCEDURE...
Page 61: ...HROSystems Horizon Seafari Self Contained and Modular Style Page F 10 NOTES...
Page 63: ...HROSystems Horizon Seafari Self Contained and Modular Style Page F 12 NOTES...
Page 64: ...SECTION G SYSTEM START UP PROCEDURE...
Page 69: ...HROSystems Horizon Seafari Section G System Start Up Procedure Page G 5...
Page 70: ...SECTION H SHUTDOWN PROCEDURE...
Page 74: ...SECTION I SYSTEM TROUBLESHOOTING GUIDE...
Page 90: ...HROSystems Horizon Seafari Self Contained and Modular Style Page I 16...
Page 114: ...SECTION L EXPLODED PARTS VIEWS WITH DESCRIPTION PART NUMBERS...
Page 135: ...APPENDIX A WIRING INFORMATION DIAGRAMS...
Page 148: ...APPENDIX B...
Page 156: ...HROSystems Horizon Seafari Self Contained and Modular Style APPENDIX B 8 NOTES NOTES...