H-50
Vertical Line
The vertical line on the graph shows the current master channel
position. When the master channel is deflected fully in one
direction, the line is to the extreme left over Point-L. When it
is at neutral, it is in the center over Point-1 and when it is fully
deflected in the other direction, the cursor is at the extreme right
of the graph over Point-H. Where the vertical line intersects
the Curve/Line over a given point defines slave servo position,
which is equal to the value assigned to that point.
Multi-Point Programmable Mixer
Graph
The graph illustrates the mixing curve. The X-Axis (horizontal
plane) represents master channel movement. The Y-Axis
(vertical plane) represents the slave servo movement where the
bottom 1/2 of the graph is one direction from neutral and the
top portion of the graph is the other direction.
Curve mixes are defaulted to three points (L, 1 and H). Up to
five additional point can be added. To add a point, move the
master channel in the desired position until STOR appears on
the left bottom of the screen. Pressing STOR will store a new
point at that position.
The Exponential function blends the curve between the points
on the graph to provide a smooth response. The default value is
OFF. To turn it on and smooth the mixing curve, highlight and
select OFF and it will toggle to ON.
Slave Channel Position
Exponential
Points that Can Be Added and Adjusted
The slave servo position next to OUT at the bottom left of the
display is expressed in values from -100 to +100, with 0 being
neutral or center. It represents the servo travel that corresponds
to the present master channel position.
Note
: To eliminate a point press ERAS (bottom left of the
screen) when the point is highlighted.
Summary of Contents for JR DSM 12X
Page 191: ...W 5 ...