Installing the Control
3-23
Mounting and Wiring the Panel Link Module
•
The PLM will not operate until the device is enabled in the control’s
Device Programming in #93 Menu Mode.
•
Do not mount the PLM on the cabinet door or attempt to attach it to the PC board.
To mount and wire the Panel Link Module, refer to
Figure 3-27
and
perform the following steps:
Step Action
1
Remove all power from the control panel before making any wiring connections.
2
Mount the module in the control cabinet if space is available or, adjacent to the cabinet, using 2-faced
adhesive tape.
3
Set the PLM’s DIP switches for a device address between 01 and 30. See the module’s instructions for the
DIP switch table.
Do not use an address being used by another device (keypads, RF receivers, etc.).
4
Connect the 12V (+) and (–) and data-out and data-in connections from the PLM to the control’s keypads
terminals (6, 7, 8, and 9), respectively.
5
Connect the 3-wire RS-485 cable between each PLM. Recommended wiring is to bring the wires “in” from
one module (or control panel) to terminals 5 (+), 6 (-), and 7 (G) and “out” to the next module from terminals
TB1-8 (+), 9 (-), and 10 (G).
+
_
G
+
_
G
+
_
1 2 3 4 5 6 7 8
PLG-002-V0
RS-485
RS-485
EOL
JUMPER
PINS
PIEZO
SOUNDER
TAMPER
REED
SWITCH
DIP
SWITCH
ECP IN
ECP OUT
Figure 3-27: VA8200 Panel Link Module Wiring
Communicator Connected to the J7 Triggers
These triggers may be used to trip auxiliary alarm signaling equipment such as Honeywell’s 7845GSM, 7845iGSM, and
7847i, Communicators. The triggers are common to all partitions and must be enabled for each partition (field 2
✳
20).
The fire and burglary/audible panic alarm triggers are normally LOW and go HIGH until a
User Code + OFF
is
entered in all enabled partition(s) that display these conditions. The silent panic/duress trigger latches HIGH, except for
duress, which is momentary.
Refer to the installation instructions that accompany your Communicator for the connections to the control panel.
Communicator Connected to the ECP
The control can support an ECP Communicator (7845GSM, 7845i-GSM, 7845i-ent and 7847i are supported) that
connects to control panel’s keypad terminals. All messages programmed for transmission via the phone lines may also
be sent via the Communicator. These messages are transmitted in Contact ID format regardless of the format
programmed for the control in fields 45 and 47.
Summary of Contents for VISTA-128BPEN
Page 2: ......
Page 10: ......
Page 58: ...Vista 128BPEN Installation and Setup Guide 3 38 ...
Page 82: ...Vista 128BPEN Installation and Setup Guide 5 14 ...
Page 102: ...Vista 128BPEN Installation and Setup Guide 8 2 ...
Page 118: ...Vista 128BPEN Installation and Setup Guide C 2 ...
Page 126: ......