3
INSTALLATION
28
SMARTLINE® RM60 (FMCW)
www.honeywell.com/ps
34-VF-25-31 iss.4 GLO December 15 US
3.7.2 How to install a device with a threaded connection
Equipment needed:
•
Device
•
Gasket for G 1
½
connection (not supplied)
•
50 mm / 2
¨
wrench (not supplied)
If the antenna is smaller than the process connection:
•
Make sure the silo connection is level.
•
Make sure that you use the applicable gasket for the connection dimensions and the process.
•
Align the gasket correctly.
•
Lower the antenna carefully into the silo.
•
Turn the threaded connection on the housing to attach the device to the process connection.
•
Tighten the connection.
i
Refer to local rules and regulations for the correct torque to apply to the connection.
Requirements for threaded connections
Figure 3-10: Threaded connection
Figure 3-11: How to attach the device if the antenna is larger than the process connection